Silicon Labs /SiM3_NRND /SIM3L167_C /RTC_0 /CONTROL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CONTROL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NOT_SET)ALM0I 0 (NOT_SET)ALM1I 0 (NOT_SET)ALM2I 0 (NOT_SET)TMRCAP 0 (NOT_SET)TMRSET 0 (NOT_SET)CLKVF 0 (NOT_SET)OSCFI 0 (DISABLED)HSMDEN 0 (NOT_SET)LRDYF

HSMDEN=DISABLED, TMRCAP=NOT_SET, ALM1I=NOT_SET, OSCFI=NOT_SET, TMRSET=NOT_SET, LRDYF=NOT_SET, ALM0I=NOT_SET, CLKVF=NOT_SET, ALM2I=NOT_SET

Description

RTC Control

Fields

ALM0I

Alarm 0 Interrupt Flag.

0 (NOT_SET): Alarm 0 event has not occurred.

1 (SET): Alarm 0 event occurred.

ALM1I

Alarm 1 Interrupt Flag.

0 (NOT_SET): Alarm 1 event has not occurred.

1 (SET): Alarm 1 event occurred.

ALM2I

Alarm 2 Interrupt Flag.

0 (NOT_SET): Alarm 2 event has not occurred.

1 (SET): Alarm 2 event occurred.

TMRCAP

RTC Timer Capture.

0 (NOT_SET): RTC timer capture operation is complete.

1 (SET): Start the RTC timer capture.

TMRSET

RTC Timer Set.

0 (NOT_SET): RTC timer set operation is complete.

1 (SET): Start the RTC timer set.

CLKVF

RTC External Oscillator Valid Flag.

0 (NOT_SET): External oscillator is not valid.

1 (SET): External oscillator is valid.

OSCFI

RTC Oscillator Fail Interrupt Flag.

0 (NOT_SET): Oscillator is running.

1 (SET): Oscillator has failed.

HSMDEN

RTC High Speed Mode Enable.

0 (DISABLED): Disable high speed mode. (AHBCLK < 4x RTCnTCLK)

1 (ENABLED): Enable high speed mode. (AHBCLK >= 4x RTCnTCLK)

LRDYF

RTC Load Capacitance Ready Flag.

0 (NOT_SET): The load capacitance is currently stepping.

1 (SET): The load capacitance has reached its programmed value.

Links

()